FUJITSU C150-E049-02EN User Manual
Page 184
M3099GX/GH OEM Manual
5-5
ERROR
PROCESSING
AND RECOVERY
Table 5.2 Device and operator actions for equipment errors (Continued)
LCD display
Scanner actions (*1)
Action to recover
LAMP ALARM 1
LAMP ALARM 2
HEATER ALARM 1
HEATER ALARM 2
CCD UNIT
ALARM 1
CCD UNIT
ALARM 2
TEMP. ALARM
FUSE ALARM
*
RAM ALARM
*
TIME-OUT
*
ALARM PRINT
- The Check lamp lights
and an error message is
displayed on the LCD
display.
- The normally scan
document is ejected to
the stacker and the
mechanism system is
stopped.
- Check if the lamp or
heater is attached
correctly. Replace
lamp according to the
replacement method.
- If turning the power
on again does not
recover the scanner,
contact the
maintenance staff.
EEPROM
ALARM
RAM 6 to 9
ALARM
V-RAM 1 to 4
ALARM
- The Check lamp lights
and an error message is
displayed on the LCD
display.
- The FAIL signal on.
HARDWARE ALARM
- If turning the
power on again
does not recover
the scanner,
contact the
maintenance
personal.
PROGRAM
ERROR
Check if the termi-
nator is installed.
* Endorser option only
*1: Common action at equipment error is the buzzer activated for 3
seconds.
#05 Chapter 5
98.2.22, 1:51 PM
5