3-46
M3099GX/GH OEM Manual
Brightness Step:
FFh(255 steps)
Brightness Step field indicates available steps of the Brightness. If
zero is pecified, Brightness Control is not supported.
Threshold Step:
FFh(255 steps)
Threshold Step field indicates available steps of the Threshold. If
zero is pecified, Threshold Control is not supported.
Contrast Step:
FFh(255 steps)
Contrast Step field indicates available steps of the Contrast. If zero is
pecified, Contrast Control is not supported.
Number of Resident Dither:
0100xxxxb(4 patterns)
Number of Resident Dither field indicates number of resident
Dither patterns in 4 bits. If zero is specified no dither pattern is
available.
Number of Registerable Dither: xxxx1000b(8 patterns)
Number of Registerable Dither field indicates registrable dither
patterns in 4 bits. If zero is specified no dither pattern is registrable.
Number of Resident Gamma Function: 0100xxxxb(4 patterns)
Number of Resident Gamma Function field indicates number of
resident gamma functions in 4 bits. If zero is specified no gamma
function is available.
Number of Registrable Gamma Function: xxxx1000b(8 patterns)
Number of Registrable Gamma Function field indicates registrable
gamma functions in 4 bits. If zero is specified no gamma function is
registrable.