beautypg.com

FUJITSU MHK2090AT User Manual

Page 140

background image

5.3 Host Commands

C141-E088-03EN

5-67

Table 5.10 SMART error log data format (2/2)

Byte

Item

44

Error log 1

Error data

Device/Head register

45

Status register

46 to 58

Vendor unique

59

Status

5A, 5B

Total power on time [hour]

5C to 1C3

Error log 2

to

Error log 5

(The format of each error log is the same as Byte 02 to
5B.)

1C4, 1C5

Number of unrecoverable errors that have occurred.

1C6 to 1FE

Reserved

1FF

Check sum

Error log index

Indicates the latest error log number. If an error has not occurred, 00 is
displayed.

Error log 1 to 5

When an error occurs, the error log index value is incremented and
information at the time the error occurred is recorded in the error log area
specified by this value. When the error log index exceeds 05, it returns to 01.

Command data 1 to 5

Indicates five commands data in order received by the device until the error
occurs. Commands for which an error occurred are included in Command
Data 5.

Error data

Indicates the I/O register values when the error is reported.

Status

Bits 0 to 3:

Indicates the drive status when received error commands
according to the following table.

Bits 4 to 7:

Vendor unique