FUJITSU MHK2090AT User Manual
Page 130
5.3 Host Commands
C141-E088-03EN
5-57
At command issuance (I/O registers setting contents)
1F7
H
(CM)
X’98’ or X’E5’
1F6
H
(DH)
Ч
Ч
Ч
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
Ч
Ч
Ч
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
X’00’ ,X’80’ or X’FF’
Error information
(29) SMART (X’B0)
This command performs operations for device failure predictions according to a
subcommand specified in the FR register. If the value specified in the FR register
is supported, the Aborted Command error is posted.
It is necessary for the host to set the keys (CL = 4Fh and CH = C2h) in the CL
and CH registers prior to issuing this command. If the keys are set incorrectly, the
Aborted Command error is posted.
In the default setting, the failure prediction feature is enabled.
The device collects or updates several items to forecast failures. In the following
sections, the values of items collected or updated by the device to forecast failures
are referred to as attribute values.