Check sum

Two’s complement of the lower byte, obtained by adding 511-byte data one
byte at a time from the beginning.

Insurance failure threshold

The limit of a varying attribute value. The host compares the attribute values
with the thresholds to identify a failure.

If an unrecoverable error is detected during execution of a command received by
the device from the host computer, the device saves the SMART error log on the
disk medium.

The host computer can issue the SMART Read Log Sector sub-command (FR
register = D5h, SN register = 01h) and read the SMART error log.

Table 5.10 SMART error log data format (1/2)

Byte

Item

00

Error log version number

01

Error log index

02

Error log 1

Command Data 1

Device Control register

03

Features register

04

Sector Count register

05

Sector Number register

06

Cylinder Low register

07

Cylinder High register

08

Device/Head register

09

Command register

0A to 0D

Elapsed time [ms] from the
point when the power is turned
on until command reception

0E to 3D

Command Data 2 to 5

(The format of each type of
command data is the same as
that of byte 02 to 0D.)

3E

Error data

Reserved

3F

Error register

40

Sector Count register

41

Sector Number register

42

Cylinder Low register

43

Cylinder High register