FUJITSU MHV2160BT User Manual
Page 184

Interface
5-108
C141-E239
Table 5.34 Information to be read by IDENTIFY DEVICE command (3/3)
Word Value
Description
117-118 X’
0100’
Number of words for logical sectors
119
X’400x’
Features Implemented Word (Supported Settings)
*27
120
X’400x’
Features Enable Word (Enable Settings)
*28
121-127 X’0000’ Reserved
128 X’0001’
Security
status
*29
129-159 X’xxxx’ Undefined
160-205 X’0000’ Reserved
206
X’003D’
SCT command sets support
*30
207-209 X’0000’ Reserved
210-211 X’xxxx’ (Option)
Number of verify sectors when Write Read
Verify function Mode 3 is specified
*31
212-213 X’xxxx’ (Option)
Number of verify sectors when Write Read
Verify function Mode 2 is specified
*32
214-254 X’0000’ Reserved
255
X’xxA5’
Check sum (The 2 complement of the lower order byte resulting from
summing bits 7 to 0 of word 0 to 254 and word 255, in byte units.)
*1 Word 0:
General configuration
Bit 15:
ATA device = 0, ATAPI device = 1
Bits 14-8: Undefined
Bit 7:
Removable disk drive = 1
Bit 6:
Fixed drive = 1
Bits 5-3: Undefined
Bit 2:
IDENTIFY DEVICE Valid = 0
Bits 1-0: Reserved