beautypg.com

3 diagnostic flowcharts, 1 group 1 error flowchart (lamp assembly), 2 group 2 error flowchart (flatbed/adf motor) – FUJITSU SCANPARTNER 600C User Manual

Page 93

background image

5-3

5.3 Diagnostic flowcharts

Use the flowcharts that follow to determine the exact problem when either the online or offline diagnostics
indicate a group error. Refer to Chapter 4 for parts replacement.

5.3.1 Group 1 error flowchart (Lamp assembly)

This flowchart applies when the Ready and the Paper Jam LED each blinks 6 times the same while, with the

scanner offline.

Yes No

5.3.2 Group 2 error flowchart (Flatbed/ADF motor)

This flowchart applies when the offline diagnostics error indication is the simultaneous blinking 5 times of

the Ready and Paper Jam LED.

Group 1 Error

CCD error
Replace optical
assembly

Lamp is on?

Inverter error
Replace lamp
inverter circuit

Lamp is on?

Replace the lamp

End of test

Yes

No

Group 2 error

Flatbed

motor

moves?

Flatbed motor error

Replace flatbed
motor

ADF/Flatbed home

position sensor error

Replace home

position sensor

No

Yes