4.7.2 Read sequence

The following illustration is an example of the command sequence used with this scanner. All commands
are assumed to be issued from a single initiator.

4.7.2.1 Read sequence for B&W mode

Initiator

Target

(Not required if ADF is not used)

(See section 4.7.3 for the READ command sequence)

(Not required if ADF is not used)

(Not required if ADF is used because document is unloaded automatically)

4.7.3 READ command sequence

4.7.3.1 Single READ

READ command

Request image data (TL).

Start scanning

(one page)

Command completion

Send image data (TL).

Move to reserved status

RESERVE UNIT

- Set window parameters

- Calculate the number of scan

lines covering all windows set
up, in terms of lines effective
after magnification change

SET WINDOW

OBJECT POSITION

Unload document from ADF

OBJECT POSITION

OBJECT POSITION

Start scan/transfer

Release reserve state

READ command sequence

RELEASE UNIT