beautypg.com

FUJITSU SCANPARTNER 600C User Manual

Page 64

background image

4-36

(c) Window identifier: Byte 0

Specifies a unique value that identifies a window. The value may be 0 to

255.

If two or more

window

identifiers are specified for a single set of window data, the most recently specified identifier is
validated This scanner allows only one window to be set Therefore, only 0 may be specified in this
field. II other than 0 is specified, this scanner returns the following error:

Status: B~0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(d)

Auto: Byte 1
This scanner does not support auto. If a value other than 0 is specified, this scanner returns the foIl
error:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(e) X, Y resolution (XR, YR): Bytes 2 to 3 and 4 to 5

Specified here are the resolutions in the horizontal (X) and vertical (Y) scanning directions, in pixels
per
inch. If 0 is specified, the default value (300 dpi) is assumed. The acceptable resolution value is as
60, 75, 80, 100, 120, 150, 200, 240, 300, 600. If a value is specified that does not comply with these
conditions, this scanner returns the following error:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(f) Upper left X,Y(ULX, ULY): Bytes 6 to 9, A to D

Specified here are the X and Y coordinates of the upper-left comer of the window. The coordinates
expressed in units of 1/1200 inches relative to the upper-left comer of the maximum scan area. If the
ULX or ULY value is outside the maximum scan area of this scanner, this scanner returns the
following error:

Status: B'00001'(CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(g) Width, length (W, L): Bytes E to 11, 12 to 15

Specifies here are the width and length of the window, in units of 1/1200 inches. If the W or L value
outside the maximum scan area of this scanner; the following error is returned:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

The same error is also returned if this scanner is set to less than one raster line for vertical scanning
less than two bytes for horizontal scanning.
Notes:
1.

ULX, ULY, W, L versus maximum scan area:
0< (ULX + W)

ó 10200 (in 1/1200 inches)

0< (ULY + L)

ó 13937 (in 1/1200 inches) for flatbed scan

0< (ULY + L)

ó- 16800 (in 1/1200 inches) for ADF scan

2.

Conditions for horizontal scanning:
9< {XR x W/1200]

у 5100