6 test unit ready command, 2 contents of self-test, 3 results of self-test – FUJITSU SCANPARTNER 600C User Manual
Page 59
4-31
(C)
DO (device offline), UO (unit offline): Byte 1
This scanner ignores DO and UO.
(d) Parameter list length: Bytes 3 to 4
This scanner does not support parameter list length.
4.4.5.2 Contents of self-test
The contents of self-test shall be an equivalent of NOP, provided that CHECK CONDITION is reported if err
information is withheld in the unit.
4.4.5.3 Results of self-test
This scanner reports the results of self-test as follows:
(a) Normal
The GOOD status is returned.
•
Status: B'00000' (GOOD)
•
Sense key: X'O' (NO SENSE).
(b) Abnormal
If error information is being withheld, the following status is returned:
•
Status: B'00001' (CHECK CONDITION)
•
Sense key: Error information being withheld
4.4.6 TEST UNIT READY command
The following table shows the normal sequence of the TEST UNIT READY command when used with this scanner.
Table 4-15
Step
Bus phase
Initiator operation
←
←→
→
Target
operation
1
BUSFREE
Verifies bus free
2
ARBITRATION
Obtains bus-usage right
3
SELECTION
Select target
→
Drives BSY
signal
4
MESSAGE OUT
Selects logical unit
→
5
COMMAND
Specifies TEST UNIT READY (CDB)
→
6
STATUS
Reports GOOD
status
7
MESSAGE IN
←
Reports message
(Command
Complete)
Releases BSY
signal
8
BUS FREE