beautypg.com

Target) – FUJITSU SCANPARTNER 600C User Manual

Page 58

background image

4-30

Table 4.14 SEND DIAGNOSTIC command

Step

Bus phase

Initiator operation

←→

Target operation

3

SELECTION

Selects target

Drives BSY signal

4

MESSAGE

Selects logical unit

OUT

5

COMMAND

Specifies SEND

Performs self-test

DIAGNOSTIC
(CDB)

6

STATUS

Reports GOOD status

7

MESSAGE

Reports message (Command Complete)

IN

Releases BSY signal

8

BUSFREE

4.4.5.1 SEND DIAGNOSTIC command: COMMAND phase (initiator

target)

The SEND DIAGNO~C command is used by an initiator to request a target or local unit for self-test. Two types of
self-diagnostic are: (a) the selftest performed by the unit itself, and (b) the test conducted according to the instruction
data from the initiator.

This scanner supports the self-test only.

The results of self-test are reported using the status and sense da~

The CDB of this command is shown in the following illustration.

7

6

5

4

3

2

1

0

Operation code X'1D'

Logical unit number

PF

(Reserved)

SLFTST

DO

UO

Reserved

(MSB)

(LSB)

Control byte

(a) PF (page format): Byte 1

This scanner ignores PF.

(b) SLFTST (selftest): Byte 1

Specifies the self-test done by the unit itself. This value is 1 on this scanner.

Byte 0

1

2

3

4

5

Parameter list length