beautypg.com

7 set window command – FUJITSU SCANPARTNER 600C User Manual

Page 61

background image

4-33

4.4.7 SET WINDOW command

The following table shows the normal sequence of the SET WINDOW command when used with this

scanner.

Table 4-16 SET WINDOW command

Step

Bus phase

Initiator operation

←→

Target operation

1

BUS FREE

Verifies bus free

2

ARBITRATION

Obtains bus-usage right

3

SELECTION

Selects target

Drives BSY signal

4

(MESSAGE OUT)

Selects logical unit

5

COMMAND

Specifies SET WINDOW (CDB)

Sets window

6

DATA OUT

Specifies window data

7

STATUS

Reports GOOD status

8

MESSAGE IN

Reports message
(Command Complete)
Release BSY signal

9

BUS FREE

4.4.7.1 SET WINDOW command: COMMAND phase (initiator

target)

The SET WINDOW command is used to set a window.
The CDB of this command is shown in the following illustration.