beautypg.com

FUJITSU SCANPARTNER 600C User Manual

Page 55

background image

4-27

(a)

Allocation length: Byte 4

Specifies the storage area in bytes that tile initiator allocates for sense data If a 0 is set here, sense data is not
transferred, but this is not treated as an error. The target terminates tile DATA IN phase when it has
transferred either the bytes of sense data specified in this field or all of effective sense data.

4.4.4.2 Sense data: DATA EN phase (target

initiator)

The target creates sense data if its status is B'00001 ' (CHECK CONDITION) or if a BUS FREE error has occurred.
This scanner creates sense data when any of tile errors described later is encountered.

The sense data on this scanner is shown in tile following illustration.

7

6

5

4

3

2

1

0

Valid

Error code

Segment number

FM

EOM

ILI

(Reserved)

Sense key

(MSB)

Information bytes

(LSB)

Additional sense length

(MSB)

Command-specific information byte

LSB

Additional sense code

Additional sense code qualifier

Field replaceable unit code

SKSV

Sense-key specific bytes

(a)

Valid: Byte 0
Indicates whether or not the INFORMATION BYTES field is as specified by ANSI.

This scanner

returns

B'1' ("specified by ANSI").

(b)

Error

code: Byte 0

Differentiates between current error or deferred error. This scanner returns X'70' ("CURRENT ERROR").

(c)

Segment number: Byte 1

This scanner does not support SEGMENT NUMBER. This scanner returns X'00'.

Byte 0

1

2

3

6

7

8

B

C

D

E

F

10

11