Figure 27. change access codes displays, Figure 28. baud rate display – Interlogix KTD-405 Series User Manual User Manual
Page 30

KTD-405/KTD-405A/KTD-405-2D Controller Keypad
User Manual
26
14. Press esc to exit to the PROGRAM SOFT KEYS display.
15. Pressing or the
-
side of the zoom, focus,
or iris key takes you to the CHANGE 
ACCESS CODES display (Figure 27). If you 
press +, the menus in Figure 27 will appear 
in sequence. They allow you to change the 
codes used to access the user, remote, and 
supervisor menus.
The fourth display in the series allows you to 
set the access code for the keypad itself. The 
default value of zero means that operation is 
normal. (That is, no code is required.) Any 
other value means that you must enter that 
number followed by the Enter key in order to 
have access to the keypad.
Access will time out after a period of 
inactivity. The length of that period is set at 
the display in Figure 30 on page 27.
The series of four displays is activated only 
when you press + at the first display in 
Figure 27. You can navigate forward and 
backward within the displays themselves, 
but these displays will not appear when you 
navigate backward from the BAUD RATE 
display. Choosing - or 
from the
CHANGE ACCESS CODES display.
Figure 27. CHANGE ACCESS CODES displays
16. Pressing or the
-
side of the zoom, focus,
or iris key (in Figure 27) takes you to the 
BAUD RATE display (Figure 28). To change 
the baud rate used for RS-485 
communication, enter the value here. Zero is 
the default value and selects the baud rate 
normally used for either standard systems or 
HDS systems using a system controller (see 
the following menu). Standard operation in 
either Digiplex or zone mode uses 9600 bps. 
The default value automatically switches to 
the proper rate for the type of system you 
will use the keypad in. If you choose another 
rate in the screen (9=9600, 19=19200, 
38=38400), that rate is used whether in 
standard or System Controller mode. All 
other elements on the RS-485 bus must be 
set to the same rate. 
Figure 28. BAUD RATE display
CHANGE ACCESS 
CODES?
USER MENU ACCESS
CODE: 579
NEXT
REMOTE PROGRAMMING 
ACCESS
SUPERVISOR MENU 
ACCESS
LOCAL USER CODE 0
0=NORMAL
NEXT
BAUD RATE (KBOS) 0
0=DFLT, 9, 19, 38