MAXCS 7.0 Update 1MultiVoIP Configuration Guide

Page 18 of 27

Outgoing Calls to PSTN Using Out Call Routing (Optional)

To make a call to the outside though the MVP gateway requires dialing a number with a “strange” prefix,

which may not be intuitive for most users.
For example, users may expect to dial “914081231234” instead of “8-1-222-14081231234.”
Proper configuration of out-call routing in MaxCS can resolve this problem. For more information on

configuring out-call routing, refer to the Out Call Routing chapter in the MaxCS Administration Manual or

search for “routing” in the MaxCS online Help system.

Ethernet

MaxCS

IP Address

10.10.0.237

Ext 251

MVP 410

Ext 252

VPN/

Frame

Relay

Router

Router

IP Address

10.10.101.81

AltiGen IP phone

Ext 210

IPAddress

10.10.50.30

Ext 104

PSTN

Trunk Number

5102520001

5102520002

Tel 4081231234

Trunk Number

4092530001

Tel 5102520004

Figure 3: Using Out Call Routing

This section shows steps for the following example configuration:

The IP address of MaxCS at headquarters is 10.10.0.237

MaxCS has one analog extension, extension 104

The home area code of the MaxCS system is 409

The MaxCS system has several analog trunks attached where the number is 4092530001.

In the remote site, the IP address of the MVP gateway is 10.10.101.81

Two trunks are attached to MVP gateway FXO ports where the numbers are 5102520001 and

5102520002