DT220 Users Manual version 1.a Configuration Parameters

24

Clock Adjust (0)

The clock adjust parameter adds or subtracts seconds / day from the time of day clock.

Enter a positive number to add seconds or a negative number to subtract seconds / day

form the time of day clock.

ID Database

Use the ID Database menu to configure the DT220’s built in database. Selections 1..6 are

used to configure the 6 database tables available in the DT220. Selection 7 provides a

means of setting the printer ticket and transaction sequence number. Selection 8 provides

a means of resetting the ID tables to default. Selection 9 is to rebuild a corrupted

database.

Database Tables (selection 1..6)

The display provides the following menu for each table:

1 Table Name: Nnnnnnn

2 Edit Table Options

3 Edit Numeric Register Names

4 Edit Text Register Names

The Table Name is used in prompts and printing to identify the ID table being worked

on. The default table names are:

Table 1: Vehicle

Table 2: Customer

Table 3: Product

Table 4: Transaction

Table 5: ID5

Table 6: ID6


The Edit Table Options menu has the following selections and functions.

Disable table edit

: Y/N

Disable numeric register edit 1&2 : Y/N

Disable numeric register edit 3&4 : Y/N

Disable numeric register edit 5&6 : Y/N

Disable text register edit 2&3

: Y/N

Disable text register edit 4&5

: Y/N

Auto erase ID records

: Y/N


Disable table edit, if “Y” (yes) is selected the table will become read only disabling the

ability to edit/change any of the table values from the keyboard using the ID Tables key