DT220 Users Manual version 1.a Configuration Parameters
21
1 - AND:
Status:
OL (overload), ST (stable), US (unstable, in motion)
Mode:
GS (gross mode), NT (net mode)
Polarity:
+ (positive weight), - (negative weight)
Weight:
7 characters data, NOT zero blanked, with decimal point
Units:
lb, kg, t (ton), tn (tonne), g
Terminate:
lf, cr (line feed, carriage return)
2 - CONDEC:
Polarity:
space (positive weight), - (negative weight)
Weight:
7 characters, zero blanked, with decimal point
Units:
L (lb), K (kg), T (ton), G (gram), O (oz)
Mode:
G (gross mode), N (net mode)
Status:
Terminate:
lf, cr (line feed, carriage return)
3 - WEIGHTRONIX:
Mode1:
space (gross mode), 0 (zero if net mode)
Mode2:
G (gross mode), N (net mode)
Polarity:
+ (positive weight), - (negative weight)
Weight:
6 characters, NOT zero blanked, with decimal point
Units:
lb, kg, oz, g
Terminate:
lf, cr (line feed, carriage return)
4 - OHAS:
Polarity:
space (positive weight), - (negative weight)
Weight:
7 digits, zero blanked, with decimal point
Units:
lb, kg, oz, g
Mode:
G (gross mode), N (net mode)
Status:
Terminate:
lf, cr (line feed, carriage return)
5 - Transmits the contents of DT220 registers.
Data entered into a text register can include other register data. Example of register 128
(Text1) emulating a Condec format without the polarity or status in Gross mode with lbs
units. Set TX Continuous Format setting to 128 and configure text register 128 to: