6. Trouble

Shooting

Symptom

Action

Verify power from the source.

No power light.

Check fuse. If necessary, for a 115VAC
system, replace the 10-amp Time-Lag 5x20
Glass Fuse. (Pulsafeeder Part #: 05-052-17)

or

If necessary, for a 230VAC system, replace the
5-amp Time-Lag 5x20 Glass Fuse.
(Pulsafeeder Part #: 05-053-18)

Verify wiring.

No power to pump.

Low level alarm is on. Refill tank.

Float is stuck in wand. Pull wand out and rinse
with water.

Solution in tank is OK but the alarm is still
on.

Wand float is installed backwards. Remove
and reverse wand float direction.

Pump won’t feed.

Pressure switch not activating. Check pressure
switch settings.

Strainer screen is clogged. Clean strainer.

Pressure relief valve is closed. Re-adjust
pressure relief valve.

Pump continuously runs.

Pressure switch stuck open. Re-adjust pressure
switch.

Refer to Pump won’t feed.