13 data log – GLOBALSAT TR-206 User Manual
Page 79
78
13 Data Log
The function of Data Log is used to record the GPS location information in TR-206.
The recording criteria may based on time interval or/and traveled distance. If
traveled distance criterion is selected, GPS must be turned on to calculate the
moving distance. If both criteria are applied, then the device will save one record if
any one of the criteria is matched and resets the counting.
If you want TR-206 to store position according to traveled distance,
you have to extra make GPS on. Please refer to “Chapter 5 GPS.”
The recorded information can be uploaded to PC by USB interface or be
transmitted to server by GPRS remotely.
To enable data log function, you should configure parameters ‘O2’ & ‘OH’ and send
‘N8’ command. Command ‘N9’ is used to disable the function. The related
parameters are listed below.
Codeword
Parameters
Value
Description
O2
Data logger interval
u16, in seconds
0 ~ 65535
0=disable
OH
Data logger distance
u32, in meters
0 ~ 4 Giga
0=disable
Command Codeword
Parameters
N8
Enable Data logger
N9
Disable data logger
Example 1:
Enable data log function with 10 seconds interval.
GSC,123456789012345,N8(O2=10)*51!
Example 2:
Enable data log function with 2 minutes interval, maximum distance=100m & GPS
always on.
GSC, 123456789012345,N8(O2=120,OH=100,C0=1)*37!