GLOBALSAT TR-206 User Manual
Page 11
10
8=Off
P
Alarm status
xx(hex digits)
bit0=SOS alarm
bit4=Geo-fence alarm
bit5=Speed alarm
bit7=Battery low alarm
Z
Geo-fence status
Empty field: no geo-fence alarm
Ixxx: get in area xxx
Oxxx: get out area xxx
Q
Report Media
xx(hex digits)
bit0=SMS
bit1=TCP
bit2=UDP
bit5=USB
bit6=Acton[0]
bit7=Action[1]
Action=00: report format 0
Action=01: report format 1
Action=10: GPS on
R
Report type
1=Ping report
2=Periodic mode report
3=On-line mode report
4=Motion mode static report
5=Motion mode moving report
6=Motion mode static to moving report
7=Motion mode moving to static report
G=Geo-fence alarm report
I=SOS alarm report
J=Low battery alarm report
K=Speed alarm report
L=Timer 0 report
M=Timer 1 report
N=Timer 2 report
O=Timer 3 report
P=L4 report
a=Power on report (manual)