9 timer, 1 timer 0, 2 timer 1~3 – GLOBALSAT TR-206 User Manual
Page 65
64
9 Timer
Timer can be used to send report or turn on GPS. There are four periodic
timers for setting specified time report. The timers are effective during the time
frame from start time to end time and the weekday defined by weekday mask.
When start time is reached, the device enables the periodic timer with defined
interval.
Start time and end time are counted in seconds from 12:00:00 AM. Weekday
mask is used to define the effective days in a week. Bit 0 ~ bit 6 are used to
activate the time on Sunday ~ Saturday respectively. If the bit is set, the timer
is enabled on that appropriate day. Weekday mask is represented by 2 hex
digits.
Timer 0 operates differently from other timers. When there is a new event
(report), it will re-start to count down the report interval again.
Timer 1 ~ 3 will not re-start counting down the report interval when there is a
new event.
9.1 Timer 0
The configuration parameters of timer 0 are listed below.
Code
word
Parameters
Value
Description
W0
Start time
u32
0~86399
W1
End time
u32
1~86400
W2
Report interval
U16
1~65535
W3
Weekday mask
00~7f
u8, xx(hex digits)
W4
Report Media
Media
type
Please refer to 2.9 Report
media
9.2 Timer 1~3
The configuration parameters of timer 1~3 are listed below.
(“X”: Timer 1, “Y”: Timer 2, “Z”: Timer 3,)