Arnings – 8e6 Technologies ER 4.0 User Manual
Page 60

A
DMINISTRATOR
S
ECTION
C
HAPTER
2: C
ONFIGURING
THE
ER S
ERVER
52
8
E
6 T
ECHNOLOGIES
, E
NTERPRISE
R
EPORTER
A
DMINISTRATOR
U
SER
G
UIDE
W
ARNINGS
The ER will generate NetBIOS requests outside the network if 
IP.ID is activated and if no segment settings have been specified 
in the configuration of the R3000—causing it to log external 
traffic. To resolve this issue, the R3000 should be modified to log 
activity only within the network. If a firewall is used, it should be 
set up to prevent logging NetBIOS requests outside the network.
If using IP.ID, note that user login times are established for set 
periods of 15 minutes, and if more than one user logs onto the 
same machine during that time period, the activity on that 
machine will be identified with the first user who logged onto that 
machine. For example, the first user logs on a machine for three 
minutes and then logs off. The second user logs on the same 
machine for 11 minutes and then logs off. The first user logs back 
on that machine for 16 minutes. All 30 minutes are logged as the 
first user’s activity.
