DS33R11 Ethernet Mapper with Integrated T1/E1/J1 Transceiver
261 of 344
Register Name:
TR.TCICE2
Register Description:
Transmit-Channel Idle-Code Enable Register 2
Register Address:
81h
Bit
# 7 6 5 4 3 2 1 0
Name CH16 CH15 CH14 CH13 CH12 CH11 CH10 CH9
Default
0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Channels 9 to 16 Code Insertion Control Bits (CH9 to CH16)
0 = do not insert data from the idle-code array into the transmit data stream
1 = insert data from the idle code-array into the transmit data stream
Register Name:
TR.TCICE3
Register Description:
Transmit-Channel Idle-Code Enable Register 3
Register Address:
82h
Bit
# 7 6 5 4 3 2 1 0
Name CH24 CH23 CH22 CH21 CH20 CH19 CH18 CH17
Default
0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Channels 17 to 24 Code Insertion Control Bits (CH17 to CH24)
0 = do not insert data from the idle-code array into the transmit data stream
1 = insert data from the idle code-array into the transmit data stream
Register Name:
TR.TCICE4
Register Description:
Transmit-Channel Idle-Code Enable Register 4
Register Address:
83h
Bit
# 7 6 5 4 3 2 1 0
Name CH32 CH31 CH30 CH29 CH28 CH27 CH26 CH25
Default
0 0 0 0 0 0 0 0
Bits 0 – 7: Transmit Channels 25 to 32 Code Insertion Control Bits (CH25 to CH32)
0 = do not insert data from the idle-code array into the transmit data stream
1 = insert data from the idle-code array into the transmit data stream
Register Name:
TR.RCICE1
Register Description:
Receive-Channel Idle-Code Enable Register 1
Register Address:
84h
Bit
# 7 6 5 4 3 2 1 0
Name CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1
Default
0 0 0 0 0 0 0 0
Bits 0 – 7: Receive Channels 1 to 8 Code Insertion Control Bits (CH1 to CH8)
0 = do not insert data from the idle-code array into the receive data stream
1 = insert data from the idle-code array into the receive data stream