Register Name:
RBECB0R
Register Description:
Receive Bit Error Count Byte 0 Register
Register Address:
94h
Bit
# 7 6 5 4 3 2 1 0
Name
BEC7
BEC6
BEC5
BEC4
BEC3
BEC2
BEC1
BEC0
Default
0 0 0 0 0 0 0 0
Bits 0 - 7: Bit Error Count (BEC[0:7]) Lower eight bits of 24 bits. Register description below.
Register Name:
RBECB1R
Register Description:
Receive Bit Error Count Byte 1 Register
Register Address:
95h
Bit
# 7 6 5 4 3 2 1 0
Name
BEC15
BEC14
BEC13
BEC12
BEC11
BEC10
BEC9
BEC8
Default
0 0 0 0 0 0 0 0
Bits 0 - 7: Bit Error Count (BEC[8:15]) Eight bits of a 24 bit value. Register description below.
Register Name:
RBECR2
Register Description:
Receive Bit Error Count Byte 2 Register
Register Address:
96h
Bit
# 7 6 5 4 3 2 1 0
Name
BEC23
BEC22
BEC21
BEC20
BEC19
BEC18
BEC17
BEC16
Default
0 0 0 0 0 0 0 0
Bits 0 - 7: Bit Error Count (BEC[16:23]) Upper 8-bits of the register.
Bit Error Count (BEC[0:23]) These twenty-four bits indicate the number of bit errors detected in the incoming data
stream. This count stops incrementing when it reaches a count of FF FFFFh. The associated bit error counter will
not incremented when an OOS condition exists.
Register Name:
RBCB0
Register Description:
Receive Bit Count Byte 0 Register
Register Address:
98h
Bit
# 7 6 5 4 3 2 1 0
Name
BC7
BC6
BC5
BC4
BC3
BC2
BC1
BC0
Default
0 0 0 0 0 0 0 0
Bits 0 - 7: Bit Count (BC[0:7]) Eight bits of a 32 bit value. Register description below.