background image

maximum number of dynamic entries and static entries. Use the device so that t
total value of dynamic and static entries does not exceed the maximum number o
entries for the device. Using the device at the maximum entry capacity requires
mounted memory amount shown in "(3) Minimum required memory".

Table 4-44 Maximum Number of Dynamic and Static Entries

Item

Maximum Limit

Total

Dynamic

Static

IP unicast route entries

2,000,000/router

2,000,000/router

3,000/router

IP multicast route entries

10,000/router**

10,000/router**

-

ARP entries

4,096/RP*

4,096/RP*

4,096/router

IPX routing table entries

1,000/router

1,000/router

200/router

IPX ARP entries

256/router

-

256/router

Bridge filtering database entries

2,000/router

2,000/router

500/router

* Total maximum per router is determined by number of installable RPs for the target router model.
** It will be 1000/device in the case of PIM-SM.