Component Details

GR2K-GA-1002

3-21

Rev. 6.03

3.5.3

NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA

The NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA physically appear as Figure 3-24.

These NIFs each have one port for connection with a pair of SC 2-core optical fiber
connectors (transmit and receive). Table 3-20 shows the connector specifications.

Figure 3-24 NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,

NE1G-1SB, NE1G-1LB and NE1G-1LHBA Front Panel View

Switch and LED indication

Table 3-19 NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,

NE1G-1LB, NE1G-1SB and NE1G-1LHBA switch and function of LED
indications

Name

Name of switch
and LED

Status

Content

STATUS

LED: Green/
Yellow/ Red

Shows the operating
condition of RM.

Green: Operable operation
Yellow: Blocking and the board replaceable state.
Green blinking: Under preparation (Program being
loaded.)
Red: Fault
Extinguished: Operation not possible (Including the
device power supply being turned off)

LINE

LED: Green

Green: Ring pulse being established

ACT

LED: Green

Shows the operating
condition of each line.

Green: Line operation possible state (line open state)

LINE ERR

LED: Yellow

Yellow: Line section II/W fault detection.

R

LED: Green

Frame signal being received.

T

LED: Green

Frame signal being transmitted.

SIG-DT

LED: Green

Signal detect operation detected.

R

T

SIG-DT

LINK

ACT

LINE ERR

ST
AT
U
S

NE

1

G

-1

**

LINE 0

T

R

1000BASE-SX or
1000BASE-LX or
1000BASE-LH

Mark ** indicates 1S, 1SA, 1SB, 1L,
1LA, 1LB, 1LHA, 1LHAB, and 1LHBA.