beautypg.com

Chapter 3 component details, 1 cabinet (chassis), Chapter 3 - component details -1 – Hitachi GR2000 User Manual

Page 103: 1 cabinet (chassis) -1

background image

GR2K-GA-1002

3-1

Rev. 6.03

Chapter 3

Component Details

3.1

Cabinet (Chassis)

Table 3-1 shows the installed dimensions and the mass of each GR2000 cabinet
model. The mass assumes the case when each cabinet model is installed with full
options (maximum configuration). This table also refers to the minimum service
clearance for maintaining or installing each cabinet model, differentiated by the type
of installation (e.g., desktop, floor, and rack-mount). Figure 3-1 illustrates the
minimum service clearance for desktop or floor installation, while Figure 3-2
illustrates the same for rack-mount installation (common among cabinet models).
See Section Subsection 2.2 for the external images of these cabinet models.

Table 3-1

Installed Dimensions, Masses, and Minimum Service Clearances

Cabinet Model

Approx. Dimensions mm

Approx.
Mass kg

Type of Installation and Minimum Service
Clearance

Height

Width

Depth

GR2000-2S

90

440

480

15

Desktop: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-4S

180

440

480

25

Desktop: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-6H

360

440

480

50

Desktop: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-10H

630

440

600

110

Floor: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-20H

890

440

600

150

Floor: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-4

130

440

600

25

Desktop: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-10

750

430

600

85

Floor: See Figure 3-1.

Rack-mount: See Figure 3-2.

GR2000-20

1450

440

600

190

Floor: See Figure 3-1.