beautypg.com

HP Q153090901 User Manual

Page 43

background image

INQUIRY 12h

C

omm

an

ds

43

Vendor Specific data may be sent after the Product Revision Level.

Product Revision Level A vendor-specific string of four ASCII characters: “

CNNV

”:

C

is the codename (

G

for a Gen 3 SCSI drive,

L

for Gen 3 FC drive)

NN

are two digits that indicate the build of the variant.

V

is an ASCII character representing the OEM variant of the code. “

D

” is the

standard distribution variant.

WORM Version

The version of WORM supported.

WORM

1

The drive supports the LTO WORM specification.

OBDR string

$DR-10

” if the drive supports Tape Disaster Recovery.

Clocking

0 For FC drives.
3 For SCSI drives, indicating that the drive supports both ST and DT

transfers.

QAS

0

The drive does not support Quick Arbitration and Selection.

IUS

Information Units

0 Not supported for all drives other than SCSI.
1 Supported for SCSI drives.

Version Descriptor

These fields can be used to identify up to eight standards to which the drive

conforms. The values supported are listed below.
For SCSI drives, it is recommended that the first version descriptor is used for the

SCSI architecture standard, followed by the physical standard, if any, followed

by the SCSI protocol, followed by the appropriate SPC version, followed by the

device type command set, followed by the secondary command set, if any.
The following are the SCSI version descriptors:

Value

Standard

1

2

3

4

5–8

005Ch

0B56h

0300h

037Dh

0000h

SAM2 ANSI INCITS.366.2003
SPI4 ANSI INCITS.362:2002

SPC3

SSC2 ANSI INCITS

not used

The following are the FC version descriptors:

Value

Standard

1

2

3

4

5

6

7

8

0054h

0917h

0D7Ch

0DA0h

131Bh

1320h

0277h

021Ch

SAM-2 T10/1157-D rev 23

FCP-2 ANSI NCITS.332:1999

FC-AL-2 ANSI NCITS.350:200x

FC-FS (no version claimed)

FC-Tape T11/1315 revision 1.17

FC-FLA (no version claimed)

SPC-2 ANSI NCITS.351:2001

SSC ANSI NCITS.335:2000