Commands—introduction

34

Parameter List check

For

LOG SELECT

,

MODE SELECT

and some diagnostic commands, the associated data sent to the

drive is in the form of parameter lists. These are described under the command names in the next

chapter. Checks are performed to test the following:

Fixed and reserved fields have not been modified. Fixed fields are indicated by a number

in round brackets following the field name.

A field has been set to an invalid value.

The syntax of the page of parameters has been violated—for example, where a particular

value in one field imposes limitations on the valid range for another field.

If a field has been set to an illegal value,

CHECK CONDITION

is reported to the host with a sense

key of

ILLEGAL REQUEST

and additional sense of 2600h (invalid field in parameter list).

The drive scans the data in the Command Description Block from “left” (bit 7) to “right”, and

“down” (from byte 0 to byte n). It sets the field pointers to the first bit of the first bad field

encountered. If the bad field is contained in a contiguous group of fixed fields, the pointers

indicate the first bit of the first field in the group, even though the error may be in a later field in the

group.

NOTE:

With MODE SELECT, the drive checks the integrity of the whole parameter list before acting on

any parameters, so all the mode parameters need to be correct before any of them are implemented.

Reservation check

This checks to see if the drive has been reserved for use by a host, and if it has, whether the host is

the same host that sent the command being executed.

If the drive has been reserved for some other host then

RESERVATION CONFLICT

status is reported.

See the

RESERVE UNIT

(page 164) and

RELEASE UNIT

(page 135) commands.

Unit Attention check

This checks if a

UNIT ATTENTION

condition exists for the host which sent the command. If it does,

the drive reports

CHECK CONDITION

status with a sense key of

UNIT ATTENTION

. The remaining

sense data will be set according to the unit attention condition which exists. See Unit Attention

Sense in the description of the

REQUEST SENSE

command on page 155.