beautypg.com

HP Q153090901 User Manual

Page 160

background image

Commands

160

14 03h End of data not found

A read-type operation failed because a format violation

related to a missing EOD data set, or there was an attempt

to read a brand new tape.

1A 00h Parameter list length error

The amount of data sent in a Mode Select or Log Select

command is incorrect

or

The Mode Header indicates a Mode Block Descriptor but

no Mode Block Descriptor is sent.

20 00h Invalid command operation code The operation code in the command was not valid.

24 00h Invalid field in Command

Descriptor Block

An invalid field has been detected in a Command

Descriptor Block.

25 00h LUN not supported

The command was addressed to a non-existent logical unit

number.

26 00h Invalid field in parameter list

An invalid field has been detected in the data sent during

the data phase

26 01h Parameter not supported

The command was addressed to a non-existent logical unit

number.

26 04h Invalid release of persistent

reservation

The Persistent Reservation holder has tried to release the

persistent reservation using the PERSISTENT RESERVE OUT

command, but the Scope or Type supplied was invalid.

27 00h Write-protected

A write-type operation has been requested on a tape that

has been write-protected.

28 00h Not ready to ready transition,

medium may have changed

A tape has been loaded successfully into the drive and is

now ready to be accessed.

29 01h Power-on reset

The drive has powered on since the host last accessed it.

29 02h SCSI bus reset

SCSI drives:

The drive has received a SCSI reset signal

since the host last accessed it.

FC drives:

The drive has received its first process login. The

drive will be implicitly logged out after a Target Reset so

this ASCQ will be posted after the host has performed

port/process login.

29 03h Bus device reset

SCSI drives:

The drive has received a SCSI bus device reset

message since the host last accessed it.

FC drives:

The drive has received a process login when it

was previously logged in for a particular host.

29 04h Internal firmware reboot

The drive has reset itself.

29 05h Transceivers to SE

SCSI drives:

The transceivers on the bus have been reset to

Single-Ended.

29 06h Transceivers to LVD

SCSI drives:

The transceivers on the bus have been reset to

LVD.

2A 01h Mode parameters changed

The Mode parameters for the drive have been changed by

an initiator other than the one issuing the command.

2A 02h Log parameters changed

The Log parameters for the drive have been changed by

an initiator other than the one issuing the command.

2A 03h Reservations pre-empted

A PERSISTENT RESERVE OUT command with the Clear

service action was attempted. All reservations and the

persistent reservation have been removed.

Code Description

Explanation