It is possible for multiple

UNIT ATTENTION

conditions to arise (for example, after a power-on

followed by a tape load), such that the initiator does not read one condition before the next

occurs. In this case a prioritizing scheme is used. If a

UNIT ATTENTION

condition exists and a new

one occurs, then the

UNIT ATTENTION

sense will be overwritten by the new sense only if the new

sense has a higher priority.

The order of priority is as follows:

U

NIT ATTENTION

sense that arises as a result of a command executing will not be posted to the

sending initiator, but will be set for the other initiators.

DEFERRED ERROR sense

D

EFERRED ERROR

sense is generated when an operation fails and

CHECK CONDITION

status

cannot be reported to the host for one of the following reasons:

The operation had immediate-report on (for example,

REWIND

with the Immed bit set, or

LOAD

).

The operation was a write that was immediate-reported on after its data was successfully

placed in the write-behind queue.

The operation was abandoned without status (that is, a bus release occurred) after what the

drive perceived was a catastrophic error or when an error occurred following the drive’s

honoring of an

ABORT

message. Following the bus release, the drive performed “cleanup”

activity that failed. The Deferred Error refers to the reason for this failure.

When any one of the above occurs, the sense generated will be

DEFERRED ERROR

sense. This sense

persists until the host sends a command that has Unit Attention as part of its pre-execution checks.

When the Deferred Error pre-execution check fails, the

DEFERRED ERROR

sense is moved to the

Current sense and

CHECK CONDITION

status is reported to the host. The host is then expected to

issue a

REQUEST SENSE

command to recover the new Current sense data, otherwise the data will

be lost.

Write-behind deferred errors:

If the Buffered Mode field of the

MODE SELECT

parameter header is not zero, data buffering is

enabled. If an error occurs in flushing the write-behind data,

DEFERRED ERROR

sense is set for all

hosts that the drive thinks have write-behind data in the buffer. For each of these hosts, the

following occurs when its next command is to be executed:

If the command is

WRITE

or

WRITE

FILEMARKS

the

DEFERRED ERROR

sense is copied to

Current sense and the error is changed to a Current error (the Error Code field is set to

70h). The information bytes will contain residue information reflecting the size of the write-

behind queue plus the transfer size of the current command.

CHECK CONDITION

is

Power-on, Reset

Tape Loaded

Mode Parameters Changed

Microcode Downloaded

highest priority

lowest priority