Part # 25000102

Installation and Operations Manual

Voltage

Code

60 Hertz Rating

50 Hertz Rating

Rating

Min.

Max.

Rating

Min.

Max.

B

230-1

207

253

-

-

-

C

208/230-3

187

253

200/220-3

180

240

D

460-3

414

506

380/420-3

342

462

E

575-3

518

633

500-3

450

550

K

208/230/460-3

187

506

200/380/400-3

180

440

M

-

-

-

380/420-3

342

462

N

230/460-3

207

506

200/400-3

180

440

U

200-3

180

220

-

-

-

Model

Factors

3D

See Copeland Application Bulletin Number AE 21-1278

Moduload - Capacity Control for 3D Compressors

Full Load

One Bank

Unloading

Two Bank

Unloading

Performance

HT

MT

LT

HT

MT

LT

HT

MT

LT

4D

CAPACITY

POWER

AMPS

1.00

1.01

1.01

1.00

1.03

1.03

1.00

1.02

1.02

.50

.56

.60

.50

.56

.60

.50

.56

.74

-

-

-

-

-

-

-

-

-

6D

CAPACITY

POWER

AMPS

1.00

1.01

1.03

1.00

1.03

1.04

1.00

1.02

1.02

.70

.70

.75

.70

.71

.77

.70

.72

.84

.36

.40

.55

.36

.42

.60

.36

.43

.72

Compressors

The majority of the Heatcraft Parallel systems incorporate the

Copeland compressor. Other brand compressors are available

upon customer request. The compressors are solid mounted

to a base frame or mounted on the refrigerant receiver. All

reciprocating compressors incorporate oil floats. Crankcase

heaters will be installed and wired. Cylinder head cooling fans

will be installed on all low temperature reciprocating systems

or as directed by the specific compressor manufacturer. A high

pressure cutout and oil failure control are installed and wired

for each compressor.

Many compressors are available with unloading for capacity

control. The unloading of a compressor adds many capacity

steps to those normally available to an electronic controller.

Usually, the more steps available the better the load can be

matched.

Copeland Compressors

Table 8. 3D/4D/6D Solid State Modules

Control Voltage

Model

Number

Copeland

Kit

Number

Copeland

Number

T.I.

Number

115 - 230 Volts

3D-FSM

4D/6D

998-0524-00

071-0524-00

31AA-1600E

Table 9. Typical Voltage Ranges

Table 10. Unloader Factors

Refer to voltage rating of specific models

Multiply compressor rating data by above factors when used with blocked suction unloading

Refer to Copeland AE 17-1287 for Demand Cooling Restrictions on unloading