beautypg.com

Dcm-500bwh – Hoshizaki DCM-500BWH-OS User Manual

Page 7

background image

7

Note: We reserve the right to make changes in specifications and design without prior

notice.

3. DCM-500BWH

AC SUPPLY VOLTAGE

115/60/1

COMPRESSOR

120 V

7.9 RLA

51 LRA

GEAR MOTOR

120 V

2.4 FLA

1/4 HP

AGITATING MOTOR

120 V

0.9 FLA

55 W

DISPENSING MOTOR

120 V

0.9 FLA

55 W

OTHERS

120 V

0.2 A

MAXIMUM FUSE SIZE

20 A

MAX. HACR BREAKER (USA ONLY)

20 A

MAX. CIRC. BREAKER (CANADA ONLY)

20 A

MINIMUM CIRCUIT AMPACITY

20 A

APPROXIMATE ICE PRODUCTION

Ambient

PER 24 HR.

Temp. (°F)

lbs./day ( kg/day )

70

* 567 (257) 549 (249) 539 (244)

Reference without * marks

80

529 (240) 519 (2335) 509 (231)

90

500 (227) * 495 (224) 481 (218)

100

472 (214) 464 (210) * 428 (194)

SHAPE OF ICE

Cubelet (Compressed Flake Ice)

ICE QUALITY

Approx. 90% Ice (90/70° F, Conductivity 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

40 lbs.

ELECTRIC & WATER CONSUMPTION

90/70°F

ELECTRIC W (kWH/100 lbs.)

967 (4.7)

POTABLE WATER

60 (12)

WATER - COOLED CONDENSER

352 (71.2)

gal./24HR (gal./100 lbs.)

EXTERIOR DIMENSIONS (WxDxH)

26" x 22-1/2" x 40" (661 x 571 x 1016 mm)

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

WEIGHT

Net 245 lbs. (111 kg), Shipping 269 lbs. (122 kg)

CONNECTIONS - ELECTRIC

Permanent Connection

- WATER SUPPLY

Inlet 1/2" FPT Condenser Inlet 1/2"FPT

- DRAIN

Outlet 3/4" FPT x2 Condenser Outlet 3/8" FPT

ICE MAKING SYSTEM

Auger type

HARVESTING SYSTEM

Direct Driven Auger ( 1/4 HP Gear Motor )

ICE MAKING WATER CONTROL

Float Switch

COOLING WATER CONTROL

Automatic Water Regulator

BIN CONTROL SYSTEM

Mechanical Bin Control ( Proximity Sw. )

COMPRESSOR

Hermetic, Model RS43C2E-CAA-219

CONDENSER

Water Cooled, Double Tube Type

EVAPORATOR

Copper Tube on Cylinder

REFRIGERANT CONTROL

Thermostatic Expansion Valve

REFRIGERANT CHARGE

R404A

14.1 oz. (400g)

DESIGN PRESSURE

High 460 PSIG

Low 290 PSIG

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out Relay

COMPRESSOR PROTECTION

Auto-reset Overload Protector

GEAR MOTOR PROTECTION

Auto-reset Thermal Protector

Fuse

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

LOW WATER PROTECTION

Float Switch and Timer

ACCESSORIES - SUPPLIED

Spare Fuse

- REQUIRED

Legs

OPERATING CONDITIONS

VOLTAGE RANGE

104-127 V

AMBIENT TEMP.

45-100°F

WATER SUPPLY TEMP.

45-90°F

WATER SUPPLY PRESSURE

10-113 PSIG

70/50°F

991 (4.1)

68 (12)

251 (44.3)

50

70

90

WATER TEMP. (°F)

ENG F-013.0.1196

This manual is related to the following products: