beautypg.com

Low ice production – Hoshizaki DCM-500BWH-OS User Manual

Page 41

background image

41

Problem

Possible Cause

Remedy

[5] All components

run, but no ice is
produced. (continued)

d) Evaporator

1. Defective.

1. Replace.

e) Water Supply Line

(water-cooled model
only)

1. Condenser water

pressure too low or
off and high pressure
control opens and
closes frequently.

1. Check and get

recommended pressure.

f) Water Regulating Valve

(water-cooled model
only)

1. Water regulating

valve set too high or
clogged (water-cooled
model only).

1. Clean, adjust, or replace.

2. Low Ice Production

Problem

Possible Cause

Remedy

[1] Low ice production.

a)Evaporator

1. Dirty or defective.

1. Clean or replace.

b)Bin Control

1. Erratic, sticking,

defective.

1. Clean or replace.

c) Drain Valve

1. Leaking water.

1. Clean or replace.

d)Expansion Valve

1. Bulb loose.

1. Secure bulb.

. Operating erratically.

. Check and replace.

e)Refrigerant Charge

1. Low charge.

1. See "V.B. Service for

Refrigerant Lines."

. Overcharge.

. See "V.B. Service for

Refrigerant Lines."

f) Refrigerant Line

1. Refrigerant line or

component restricted.

1. Repair/replace the

clogged line/component
and replace the drier.

g)High-Side Pressure

Too High

1. Dirty air filter or

condenser.

1. Clean.

. Ambient (or

condenser) water
temperature too warm.

. Reduce temperature.

3. Fan motor slow rpm.

3. See "3. [] a) Fan Motor."

4. Fan motor capacitor.

4. Check and replace.

5. Condenser water

pressure too low or off
(water-cooled model
only).

5. Check and get

recommended pressure.

6. Water regulating

valve set too high or
clogged (water-cooled
model only).

6. Clean, adjust, or replace.

h)Compressor

1. Inefficient compressor. 1. Replace
. Faulty thermal

protector (overload).

. Replace compressor.

3. Faulty capacitor/

starter.

3. Replace.