Dcm-500bwh(-os) – Hoshizaki DCM-500BWH-OS User Manual
Page 35
35
2. DCM-500BWH(-OS)
Note:
1. The data without *marks should be used for reference only.
. We reserve the right to make changes in specifications and design without prior
notice.
APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION
Temp. (°F)
PER 24 HR.
70
* 567
257
549
249
539
244
80
529
240
519
235
509
231
90
500
227
* 495
224
481
218
lbs./day ( l/day)
100
472
214
464
210
* 428
194
APPROXIMATE ELECTRIC
70
* 976
--
967
--
991
--
CONSUMPTION
80
976
--
967
--
991
--
90
976
--
* 967
--
991
--
watts
100
976
--
967
--
* 991
--
APPROXIMATE WATER
70
* 111
0.51
130
0.59
194
0.88
CONSUMPTION PER 24 HR.
80
111
0.50
130
0.59
198
0.90
(TOTAL)
90
110
0.50
* 130
0.59
203
0.92
gal. / day (kl/day)
100
110
0.50
132
0.60
* 214
0.97
EVAPORATOR OUTLET TEMP.
70
* 19
-7
19
-7
19
-7
°F (°C)
80
19
-7
19
-7
19
-7
90
19
-7
* 19
-7
19
-7
100
19
-7
19
-7
* 19
-7
HEAD PRESSURE
70
* 266
18.7
267
18.8
270
19.0
80
266
18.7
267
18.8
270
19.0
90
266
18.7
* 267
18.8
270
19.0
PSIG (kg/cm
2
G)
100
266
18.7
267
18.8
* 270
19.0
SUCTION PRESSURE
70
* 44
3.1
44
3.1
47
3.3
PSIG (kg/cm
2
G)
80
44
3.1
44
3.1
47
3.3
90
44
3.1
* 44
3.1
47
3.3
100
44
3.1
44
3.1
* 47
3.3
HEAT OF REJECTION FROM CONDENSER
PRESSURE DROP OF COOLING WATER LINE
HEAT OF REJECTION FROM COMPRESSOR
5438 BTU/h (AT 90°F /WT 70°F)
Less than 7 PSIG
1104 BTU/h (AT 90°F /WT 70°F)
50
70
90
WATER FLOW FOR CONDENSER
21 gal/h (AT 90°F /WT 70°F)