Problem

Possible Cause

Remedy

[3] No water dispensed. a) Power Supply

1. "OFF" position.

1. Move to "ON" position.

b) Water Supply

1. Water supply off or

pressure too low.

1. Check and get

recommended pressure.

c) Dispensing Water

Valve

1. Coil winding open.

1. Replace.

. Wiring to dispensing

water valve.

. Check for loose or open

connection. Repair or
replace.

d) Control Board

1. Defective.

1. See "II.D.4. Control

Board Check Procedure."

e) Water Dispense Switch 1. Opti Serve sensor

defective. (OS only)

1. See "5. Opti Serve (OS)

Sensors."

. Bad contacts. (push

button only)

. Check for continuity and

replace.

5. Opti Serve (OS) Sensors

Be sure to check all items in section "IV.C.4. Dipsensing" prior to using this chart. Use
the following charts along with the wiring diagram to troubleshoot the OS sensors.

Problem

Possible Cause

Remedy

[1] No ice dispensed.

a) OS Sensor

1. Dirty sensor.

1. Clean, using Scale Away

(6 fl. oz. (0.8 l) per 1 gal.
(3.8 l) of water) or other
non-abrasive cleaner.

. Defective.

. See chart 5a and 5b

below.

b) Dispense Mode Switch 1. Wrong setting.

1. Move to desired setting.

. Bad contacts.

. Check for continuity and

replace.

3. Loose connection.

3. Tighten.

c) Control Board

1. Loose connection.

1. Tighten.

. Defective.

. See "II.D.4. Control

Board Check Procedure"
and chart 5a and 5b
below.

[] No water dispensed. a) OS Sensor

1. Dirty sensor.

1. Clean.

. Defective.

. See chart 5c below.

b) Dispense Mode Switch 1. Wrong setting.

1. Move to desired setting.

. Bad contacts.

. Check for continuity and

replace.

3. Loose connection.

3. Tighten.

c) Control Board

1. Loose connection.

1. Tighten.

. Defective.

. See "II.D.4. Control

Board Check Procedure"
and chart 5c below.