Problem

Possible Cause

Remedy

[1] The icemaker will

not start. (Fill Cycle)
(continued)

m)High Pressure Switch

1. Bad contacts.

1. Check for continuity and

replace.

. Dirty air filter or

condenser.

. Clean.

3. Ambient or condenser

water temperature too
warm.

3. Reduce temperature.

4. Refrigerant

overcharged.

4. Recover, evacuate, and

recharge.

5. Fan not operating

(except water-cooled
model).

5. See "3.[]a) Fan Motor."

6. Refrigerant line or

components restricted.

6. Remove the restriction or

component and replace
the drier.

7. Condenser water

pressure too low or off
(water-cooled model
only).

7. Check and get

recommended pressure.

8. Water regulating

valve set too high
(water-cooled model
only).

8. Adjust it lower.

n) Plug and Receptacle

(Control Box)

1. Disconnected.

1. Connect.

. Loose terminal.

. Repair terminal

connection.

o) Control Board

1. Defective.

1. See "II.D.4. Control Board

Check Procedure."

[] Fill cycle will not

terminate.

a) Water Supply

1. Water supply off or

pressure too low.

1. Check and get

recommended pressure.

b) Float Switch

1. Connector

disconnected.

1. Reconnect.

. Float does not move

freely.

. Clean or replace.

3. Defective switch.

3. Check and replace.

c) Water Control Relay

1. Contacts sticking.

1. Replace.

. Coil winding open.

. Replace.

d) Drain Valve

1. Valve seat won't seal

and water leaking.

1. Clean or replace.

e) Hoses

1. Disconnected or

damaged.

1. Reconnect or replace.

f) Control Board

1. Defective.

1. See "II.D.4. Control Board

Check Procedure."

This manual is related to the following products: