beautypg.com

Chapter 3 quick start – EAW DSA250 & DSA230 User Manual

Page 8

background image

Chapter 3 Quick Start

This section provides basic installation requirements. Refer to Chapter 5 for
detailed instructions.

Loudspeaker refers to either a DSA230 or DSA250.

Cluster refers to any of the permissible arrangements of single or multiple
DSA230s or DSA250s as defined in DSAPilot. Whether they consist of a single
or multiple loudspeakers, all DSA clusters function as a single loudspeaker.

3 . 1

D e s c r i p t i o n

The EAW DSA Series loudspeakers are variable directivity, self-powered line
arrays. EAW’s easy-to-use DSAPilot provides computer control for the
loudspeaker’s vertical beamwidth pattern. This allows customizing the
coverage on-site to fit the application. Loudspeakers are controlled via
standard EIA-485* or optional CobraNet™/Ethernet networking.
*Also known as RS-485 (Recommended Standard 485)

Model DSA250 is a full range loudspeaker. Model DSA230 can be
employed as a voice-only loudspeaker or as low frequency loudspeaker to
supplement a DSA250’s low frequency output and pattern control.

3 . 2

A u d i o S i g n a l C o n n e c t i o n

NOTE: Using the DSAPilot, the two input channels may be summed to mono,
used separately, or set up for a priority override function: Audio B overrides
Audio A. Equalization, compression, and level are separately adjustable for
each input. Overall signal delay for each loudspeaker cluster is also provided.

Audio A and B (each): 2-conductor shielded audio cable/supplied

Phoenix Contact terminal block plug

3 . 3

C o m p u t e r C o n t r o l C o n n e c t i o n

NOTE: Set the EIA-485 Terminate Switch to “ON”. For multiple
loudspeakers, see Chapter 5.

EIA-485: 2-conductor shielded audio cable/supplied

Phoenix Contact terminal block plug

3 . 4

D a i s y C h a i n i n g A u d i o a n d C o m p u t e r S i g n a l
B e t w e e n L o u d s p e a k e r s

Distances up to 2 ft / 0.6 m are for connecting multiple loudspeakers in a
single cluster while distances over 2 ft / 0.6 m are for connecting physically
distributed clusters.

Up to 1 ft / 0.3 m: Supplied Cat-5 Signal Link Cable
Connect between Signal Link jacks (Neutrik® EtherCon®) on vertically
adjacent loudspeakers within a multi-loudspeaker cluster.

Up to 2 ft / 0.6 m: User-supplied, Cat-5 Ethernet crossover cable
Connect between Signal Link jacks (Neutrik® EtherCon®) on horizontally
adjacent loudspeakers within a multi-loudspeaker cluster.

8

AUDIO

+

AUDIO

SHIELD

Figure 3.2 Audio Connector

Figure 3.1 DSA230 & DSA250

SIGNAL

+

SIGNAL–

SHIELD

Figure 3.3 EIA-485 Connector

LINK
CABLE
P/N
0005854

Figure 3.4a Signal Links < 1 ft / 0.3