beautypg.com

EAW DSA250 & DSA230 User Manual

Page 28

background image

1. Install at least one of the supplied 1/4-20 X 3 in Retainer Bolt

with its lock washer through the side of either the top or bottom
Wall/Enclosure Bracket and snugly tighten. The bolt threads into a
weld nut on the side of the Wall Bracket. This Retainer Bolt prevents
the enclosure from being lifted off the Wall Brackets without first
removing the bolt. Note that the Retainer Bolt does not “clamp”
or support anything. It serves only to retain the enclosure on the
wall brackets, not to lock it into position.

2. Route cabling as required using the rear channels in the enclosures

extrusion.

3. Rotate the enclosure to the desired horizontal angle. Firmly tighten

each Enclosure Bracket Bolt to secure the enclosure in the desired
position.

28

1/4-20 X 3 LG

HEX HEAD SCREW

& LOCK WASHER

1/4-20 WELD NUT

Figure 5.5.9b Retainer Bolt Installation


ENCLOSURE BRACKET BOLT

CABLE CHANNELS

Figure 5.5.9c Cable Routing

Figure 5.5.9d Secure the Enclosure Position