Sony UWP-D27 2-Person Camera-Mount Wireless Omni Lavalier Microphone System (UC90: 941 to 960 MHz) User Manual
Page 465

You can copy the settings of the picture profile to another picture profile number.
MENU →
(Camera Settings1) → [Picture Profile] → [Copy].
To reset the picture profile to the default setting
You can reset the picture profile to the default setting. You cannot reset all picture profile settings at once.
MENU →
(Camera Settings1) → [Picture Profile] → [Reset].
Note
Since the parameters are shared for movie and still images, adjust the value when you change the shooting mode.
If you develop RAW images with shooting settings, the following settings are not reflected:
Black Level
Black Gamma
Knee
Color Depth
If you change [Gamma], the available ISO value range changes.
There may be more noise in dark parts depending on the gamma settings. It may improve by setting the lens compensation to
[Off].
When using S-Log2 or S-Log3 gamma, the noise becomes more noticeable compared to when using other gammas. If the noise
still is significant even after processing pictures, it may be improved by shooting with a brighter setting. However, the dynamic
range becomes narrower accordingly when you shoot with a brighter setting. We recommend checking the picture in advance by
test shooting when using S-Log2 or S-Log3.
Setting [ITU709(800%)], [S-Log2] or [S-Log3] may cause an error in the white balance custom setup. In this case, perform
custom setup with a gamma other than [ITU709(800%)], [S-Log2], or [S-Log3] first, and then reselect [ITU709(800%)], [S-Log2],
or [S-Log3] gamma.
Setting [ITU709(800%)], [S-Log2] or [S-Log3] disables the [Black Level] setting.
If you set [Slope] to +5 in [Manual Set] under [Knee], [Knee] will be disabled.
S-Gamut, S-Gamut3.Cine, and S-Gamut3 are color spaces exclusive to Sony. However, this camera's S-Gamut setting does not
support the whole S-Gamut color space; it is a setting to achieve a color reproduction equivalent to S-Gamut.
Related Topic
5-021-699-11(1) Copyright 2020 Sony Corporation
465
- DWN-02N/30A Handheld Mic Transmitter for DWX Systems (A: 566 to 607 MHz) VCL-ECF2 Fisheye Converter For SEL16F28 and SEL20F28 UWP-D22 Camera-Mount Wireless Cardioid Handheld Microphone System (UC14: 470 to 542 MHz) PCM-A10 High-Resolution Audio Recorder UTX-P40 Wireless Plug-On Transmitter (UC25: 536 to 608 MHz) 16mm Fisheye Conversion Lens for FE 28mm f/2 Lens ZV-E1 Mirrorless Camera (White) ZV-E10 Mirrorless Camera (Black) LBN-H1 Airpeak Battery Station FX6 Full-Frame Cinema Camera (Body Only)