Registration Memory

This function allows you to save virtually all panel settings to a regis-

tration memory, and you can instantly recall these setting by pressing a

single button.

Selecting a Registration Bank

Press the [BANK] button repeatedly to select a memory bank. The LCD

displays the current bank number.

The instrument provides 8 banks. Each bank has 4 registration memories

(button [1] - [4]).

Registering the Panel Settings

1.

The memory function is turned on by default when the power is turned

on. When this function is turned off, you can press the [REGISTRA-

TION] button to turn this function on, the button LED and the “MEMO-

RY” icon on LCD light up.

2.

Press and hold the [REGISTRATION] button, then press one of the

memory buttons [1] - [4] to save the panel settings to that button.

Note:

this operation will overwrite the previous data saved in that

button.

3.

Parameters that can be saved to registration memory include:

Tone:

main tone, dual tone, split tone, DSP effects, mixer settings.

Accompaniment:

style, tempo, Chord mode.

Function:

touch response, mic effect and some parameters in the

function menu.

Recalling the Registered Settings

Press one of the memory buttons [1] - [4]. It will recall the settings saved

in that button. This will reset related parameters on the control panel.

Notes:

Registration memory cannot be recalled when the O.T.S. function is in

use.

When power off, you can press and hold the [EXIT] and [ENTER] but-

tons and turn on the power. LCD display shows “Reset OK” and the

registration memory will be reset to factory default setting.