3 login in the console interface, Ogin in the, Onsole – PLANET ISW-1022MPT User Manual
Page 43: Nterface
User’s Manual of ISW-1022M Series and ISW-1033MT
43
4.3 Login in the Console Interface
To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ-45 type serial
(console) port of the Managed Industrial Switch. The console port of the Managed Industrial Switch is DCE already, so
that you can connect the console port directly through PC without the need of Null Modem.
A terminal program is required to make the software connection to the ISW Managed Industrial Switch. Windows' Hyper
Terminal
program may be a good choice. The Hyper Terminal can be accessed from the Start menu.
1. Click
START
, then Programs, Accessories and then Hyper Terminal.
2.
When the following screen appears, make sure that the COM port should be configured as:
Baud Rate: 9600 bps
Data Bits: 8
Parity: none
Stop Bit: 1
Flow control: None
The settings of communication parameters