beautypg.com

PLANET ISW-1022MPT User Manual

Page 118

background image

User’s Manual of ISW-1022M Series and ISW-1033MT

„

1

st

& 2

nd

Ring Ports:

Pull down the selection menu to assign the ports as

the member ports. 1

st

Ring Port is the working port and 2

nd

Ring Port

is

the backup port. When 1

st

Ring Port fails, the system will automatically

upgrade the 2

nd

Ring Port

to be the working port.

Enable Couple Ring:

To enable the couple ring function, tick the checkbox beside the Enable Couple

Ring

string label.

„

Couple Port: Assign the member port which is connected to the other

ring group.

„

Control Port: When the Enable Couple Ring checkbox is ticked, you

have to assign the control port to form a couple-ring group between the

two X-rings.

Enable Dual Homing:

Set up one of the ports on the switch to be the Dual Homing port. For a switch,

there is only one Dual Homing port. Dual Homing function works only when the

X-Ring function enabled.

When the X-Ring function enabled, the user must disable the RSTP. The X-Ring function and

RSTP function cannot exist on a switch at the same time.

Remember to execute the “Save Configuration” action, otherwise the new configuration will

lose when switch powers off.