User’s Manual of ISW-1022M Series and ISW-1033MT

5.8 Digital Input/Output (ISW-1033MT)

The 7 10/100TX + 3 10/100/1000T/100/1000 SFP Combo w/ X-Ring L2 Managed Industrial Switch contains two digital

inputs and two digital outputs. The digital inputs may be used to receive the voltage-changing signal of the remote

equipment to sense the state of the remote equipment like heater, pump, and other electrical equipment. Therefore the

switch can be configured to send system log, SMTP and SNMP traps to syslog server, SMTP server and SNMP trap

station respectively (please refer to System Event Log and SNMP configuration section). Outputs are open-collector

transistor switches used to connect to the external device like alarm buzzer or LED to inform the user of the port/power

status.

5.8.1 Digital Input


„

When First/Second Digital Input function is enabled, First Digital Input/Second Digital Input will then be available

respectively.

„

Digital Input:

Choose the transition type to trigger DI0/DI1.

¾

Low

ÆHigh:

Having focused this radio button, DI0/DI1 will only report the status when the external device’s

voltage changes from low to high.

¾

High

ÆLow:

Having focused this radio button, DI0/DI1 will only report the status when the external device’s

voltage changes from high to low.

„

Event description:

Please fill in the description for the event.

„

Action:

Tick the check boxes to decide whether or not to send the events via Syslog, SMTP, or SNMP Trap.

Figure 5-72

Digital Input interface

129