beautypg.com

2 electrical characteristics, 3 thermal and atmospheric characteristics, Electrical characteristics – Avago Technologies MegaRAID SATA 300-4XLP User Manual

Page 45: Thermal and atmospheric characteristics, Maximum power requirements

background image

Physical and Environmental Specifications

3-15

Version 1.4

Copyright © 2004–2006 by LSI Logic Corporation. All rights reserved.

3.3.2

Electrical Characteristics

Table 3.7

lists the maximum power requirements for the MegaRAID

SATA 300 storage adapters under normal operation.

3.3.3

Thermal and Atmospheric Characteristics

The operating (thermal and atmospheric) conditions for MegaRAID SATA
300 PCI-X storage adapters are:

Temperature range: 0 °C to 40 °C with BBU; 0 °C to 45 °C without
BBU (dry bulb)

Relative humidity range: 5% to 90% noncondensing

Airflow must be at least 200 linear feet per minute (LFPM) to avoid
operating the Intel 80331 processor above the maximum
ambient temperature

The heat sink temperature below 80 °C

Table 3.7

Maximum Power Requirements

Feature

SATA 300-8X

1

1. The total power for the SATA 300-8X has taken into consideration the charging of the BBU from the

+12 V and the on-board regulator efficiencies.

SATA 300-4XLP, SATA
300-8XLP

2

2. The total power for the SATA 300-4XLP and the SATA 300-8XLP has taken into consideration the

charging of the BBU from the +12 V and the on-board regulator efficiencies.

SATA 300-4ELP, SATA 300-
8ELP

3

3. The total power for the SATA 300-4ELP and the SATA 300-8ELP has taken into consideration the

charging of the BBU from the +12 V and the on-board regulator efficiencies.

+12 V

0.25 A if BBU
daughtercard is used

0.25 A if a remote BBU
is used

1.3 A without battery charging
1.525 A with battery charging

+5.0 V

2.2 A

2.08 A

N/A

+3.3 V

0.6 A

0.96 A

2.0 A

Power from +12 V 3 W

3 W

15.6 W without battery charging
18.3 W with battery charging

Power from +5 V

11 W

10.4 W

N/A

Power from +3.3 V 2 W

3.18 W

6.6 W

Total Power

16 W

16.8 W

24.9 W with battery charging

Operating Range

With BBU:
0 °C to 40 °C
Without BBU:
0 °C to 45 °C

With BBU:
0 °C to 40 °C
Without BBU:
0 °C to 45 °C

With BBU: 0 °C to 40 °C
Without BBU: 0 °C to 45 °C