Avago Technologies MegaRAID SAS 9240-4i User Manual
Page 31

LSI Corporation
- 31 -
MegaRAID SAS Device Driver Installation User Guide
December 2012
Chapter 6: FreeBSD Driver Installation
Updating Drivers in the FreeBSD System
b.
Move the *.c and *.h files to /usr/src/sys/dev/driver_name (which is mfi for the mfi driver and
mrsas for the mrsas driver).
c.
Move the Makefile to the /usr/src/sys/modules/driver_name (which is mfi for the mfi driver and
mrsas for the mrsas driver).
For example, to unpack the compressed driver source file and move the Makefile for the mfi driver, enter the
following commands and press Enter:
# cd /usr/src/sys/dev
# tar -xf mfi.tgz
# mv mfi/Makefile /usr/src/sys/modules/mfi/
To unpack the compressed driver source file and move the Makefile for the mrsas driver, enter the following
commands and press Enter:
# cd /usr/src/sys/dev
# tar -xf mrsas.tgz
# mv mrsas/Makefile /usr/src/sys/modules/mrsas/
5.
Go to /usr/src/sys/i386/conf if you are running a 32-bit version of the FreeBSD OS, or
/usr/src/sys/amd64/conf
if you are running a 64-bit version of the FreeBSD OS, and perform the
following steps:
a.
Copy the GENERIC configuration file to another filename. For example:
# cp GENERIC MYKERNEL
b.
Open your current configuration file (GENERIC, MYKERNEL, SMP, or PAE, or custom config), with vi or
another editor. For example:
# vi MYKERNEL
c.
Comment out the following lines by typing # at the beginning of the line:
#device cbb # cardbus (yenta) bridge
#device mpt # LSI-Logic MPT-Fusion
For a dynamically loadable module, comment out the following line by typing # at the beginning of the line:
#device mfi # LSI MegaRAID SAS
For the mrsas driver, comment out the following line by typing # at the beginning of the line, if it exists:
#device mrsas # LSI MegaRAID SAS2
For a statically linked module, make sure the following lines are not commented out:
For the mfi driver, make sure the following line is not commented out:
device mfi # LSI MegaRAID SAS
For the mrsas driver, make sure the following line is not commented out:
device mrsas # LSI MegaRAID SAS2
If you do not have a MegaRAID 92XX or earlier controller installed in your system, make sure to comment out
the following line:
#device mfi # LSI MegaRAID SAS
d.
Save your changes.
NOTE Each line is an entry in this file. Make sure a newly added entry is on a new line.
- MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID SAS 8204ELP MegaRAID SAS 8204ELP (Channel) MegaRAID SAS 8204XLP MegaRAID SAS 8204XLP (Channel) MegaRAID SAS 8208ELP MegaRAID SAS 8208ELP (Channel) MegaRAID SAS 8208XLP MegaRAID SAS 8208XLP (Channel) MegaRAID SAS 8300XLP MegaRAID SAS 8308ELP MegaRAID SAS 8344ELP MegaRAID SAS 84016E MegaRAID SAS 84016E (Channel) MegaRAID SAS 8408E MegaRAID SAS 8480E MegaRAID SAS 8704ELP MegaRAID SAS 8704ELP (Channel) MegaRAID SAS 8704EM2 MegaRAID SAS 8704EM2 (Channel) MegaRAID SAS 8708ELP MegaRAID SAS 8708ELP (Channel) MegaRAID SAS 8708EM2 MegaRAID SAS 8708EM2 (Channel) MegaRAID SAS 8880EM2 MegaRAID SAS 8880EM2 (Channel) MegaRAID SAS 8888ELP MegaRAID SAS 8888ELP (Channel) MegaRAID SAS 0260CV-4i MegaRAID SAS 0260CV-8i MegaRAID SAS 0260DE-8i MegaRAID SAS 0260DE-8i (Channel) MegaRAID SAS 9265-8i MegaRAID SAS 9280DE-8e MegaRAID SAS 9280DE-8e (Channel) MegaRAID SAS 9285-8e