beautypg.com

Additional error messages – Epson Professional Series II User Manual

Page 51

background image

Additional error messages

Error message

displayed on LCD

H OUT OF RANGE*

V OUT OF RANGE*

PLL UNLOCKED

V DEF FAILURE

H DEF FAILURE

HI VOL FAILURE

GEN FAILURE

Description

The horizontal input

signals are out of

range.

I

The vertical input

signals are out of

range.

There is a local failure

in the vertical

deflection.

I

There is a local failure

in the horizontal
deflection.

There is a local failure

in the high voltage

generator

There are two or

more problems with

the monitor

* See the note on page 38

Solution

Make sure the horizontal
input signals of the

computer’s display
adapter are within the

monitor’s horizontal

frequency range (30 to
82 KHz).

Make sure the vertical

input signals of the
computer’s display

adapter are within the

monitor’s vertical

frequency range (50 to

160 Hz).

Contact your dealer or

service representative:
the monitor needs repair

Contact your dealer or

service representative;

the monitor needs repair

Contact your dealer or
service representative;
the monitor needs repair.

Turn off the monitor, wait
five seconds, and then
turn it back on. If this does

not solve the problem,
contact your dealer or

service representative;

the monitor needs repair

Contact your dealer or
service representative,