To select the lf waveform, To set the lf amplitude, To set the lf frequency – RIGOL DSG3000 Series User Manual
Page 80

RIGOL
Chapter 2 Front Panel Operations
2-40
DSG3000 User’s Guide
To Select the LF Waveform
Press
LF Waveform to set the waveform of the LF output signal to
“Sine”, “Square”, “Triangle”, “Ramp” or “Swp-Sine” and the default is “Sine”.
To Set the LF Amplitude
Press
LF Level to set the amplitude of the LF signal.
Use the numeric keyboard to input the amplitude value and select the desired
unit from the pop-up unit menu or unit keys. You can also press Enter to select
the default unit (V).
The amplitude units available are V, mV, μV, nV and dBm.
You can press the left/right direction keys to enter the parameter editing state
and move the cursor to the specified digit and use the up/down direction keys or
knob to modify the parameter value.
You can also use the up/down direction keys or knob to modify the amplitude at
the current step.
Press Step to set the step.
The ranges of Sine, Square, Triangle and Ramp waveform amplitude are from
1mV to 3V.
To Set the LF Frequency
Press
LF Freq to set the frequency of the LF signal.
Use the numeric keyboard to input the frequency value and select the desired
unit from the pop-up unit menu or unit keys. You can also press Enter to select
the default unit (Hz).
The frequency units available are GHz, MHz, kHz and Hz.
You can press the left/right direction keys to enter the parameter editing state
and move the cursor to the specified digit and use the up/down direction keys or
knob to modify the parameter value.
After setting the frequency, you can use the up/down direction keys or knob to
modify the frequency at the current step.
Press Step to set the step.