beautypg.com

Sweep, Sweep manner, Sweep direction – RIGOL DSG3000 Series User Manual

Page 50: Sweep -10, Sweep manner -10, Sweep direction -10

background image

RIGOL

Chapter 2 Front Panel Operations

2-10

DSG3000 User’s Guide

Sweep

When the sweep function is enabled, the RF signal generator outputs RF sweep

signal from the [RF OUTPUT 50Ω] connector (as shown in the figure below) at the

front panel (at this point, RF output switch is turned on).

Sweep Manner

DSG3000 provides three sweep manners (“Freq”, “Level” and “Freq & Lev”). The

sweep function is enabled when any of the sweep manners is selected and the Swp

label will be displayed in the function status area in the user interface. By default, the

sweep function is turned off.


Press SWEEPSweep to select the desired manner.
 Off: the default state. Turn off the sweep function.
 Freq: enable the frequency sweep function. At this point, the frequency sweep

progress bar is displayed in the frequency area in the user interface.

 Level: enable the amplitude sweep function. At this point, the amplitude sweep

progress bar is displayed in the amplitude area in the user interface.

 Freq & Lev: enable the frequency and amplitude sweep functions at the same

time. At this point, the frequency and amplitude sweep progress bars are

displayed in the frequency and amplitude areas in the user interface

respectively.

Sweep Direction


Press SWEEP and use the page up/down key

to open the 3/3 menu page;

then, press Direct to select “Fwd” or “Down” and the default is “Fwd”.


 Fwd: the RF signal generator sweeps from the start frequency or start level to

the stop frequency or stop level. The progress bar in the frequency area and

amplitude area in the user interface sweeps from left to right.

 Down: the RF signal generator sweeps from the stop frequency or stop level to

the start frequency or start level. The progress bar in the frequency area and

amplitude area in the user interface sweeps from right to left.