To output rf sweep signal – RIGOL DSG3000 Series User Manual
Page 72

RIGOL
22
DSG3000 Quick Guide
the user interface. The RF output is enabled. At this point, the [RF OUTPUT
50Ω] connector outputs RF signal according to the current configuration.
Figure 9 Parameter Setting Interface (To Output RF Signal)
To Output RF Sweep Signal
This section introduces how to output a RF sweep signal by configuring continuous
linear step sweep. Set the frequency range to 1 GHz ~ 2 GHz, the amplitude range to
-20 dBm ~ 0 dBm, the number of sweep points to 10 and the dwell time to 500 ms.
1. Restore to factory setting
Press System Reset Preset Type “Factory” and then press Preset to
restore the factory setting (by default, the sweep mode is continuous, the sweep
type is step and the sweep space is linear).
2. Step sweep parameter setting
Press SWEEP and use the menu page up/down key
to turn to the 2/3
menu page; then, press Step Swp to enter the step sweep parameter setting
interface.
Start Frequency
Press Start Freq, use the numeric keyboard to input the start frequency
value (1) and select the desired unit (GHz) from the pop-up unit menu or
unit keys.